F-Gas Certified Heat Pump Engineers

Refrigerant work on a heat pump is regulated by law. Our engineers are certified to carry it out, from split system installs to leak repairs.

What F-Gas Certification Covers

A heat pump moves heat using a refrigerant, and many common refrigerants are fluorinated gases, or F-gases — powerful greenhouse gases if they escape. Under the UK's F-Gas Regulations, any work that involves handling them, from connecting a refrigerant circuit to repairing a leak, carrying out a mandatory leak check or recovering the gas, has to be done by a certified engineer.

On a monobloc heat pump the refrigerant circuit is sealed at the factory, so a standard install only involves water and electrical connections. A split system is different: the indoor and outdoor units are joined by refrigerant pipework on site, which has to be pressure tested, evacuated and charged by a certified engineer. The same goes for any repair that means opening a sealed circuit, on either type.

Some newer units, including Vaillant's aroTHERM plus, run on R290, a natural refrigerant rather than an F-gas. R290 is flammable, so those units come with their own siting and safety rules instead, and we plan the install around them.

Air source heat pump with insulated pipework installed by Allied Heating

F-Gas Work We Carry Out

  • Split system heat pump installation, including refrigerant pipework, pressure testing and charging
  • Refrigerant leak detection and repair on existing heat pumps
  • Mandatory leak checks on larger systems above the legal threshold, with the records you're required to keep
  • Refrigerant recovery when an old heat pump is removed or replaced, so nothing is vented to the air

F-Gas FAQs

No. Gas Safe registration covers work on gas and LPG appliances such as boilers, while F-Gas certification covers the refrigerants inside heat pumps. They're separate schemes and we hold both, so the same team can take out an LPG boiler and fit the heat pump that replaces it.
Many domestic heat pumps hold a small enough refrigerant charge to fall below the legal threshold for mandatory leak checks, but some older units on higher-impact refrigerants don't, and larger commercial systems usually need them. The threshold depends on the refrigerant type and how much the system holds — we'll tell you which side of it yours sits on.
It's recovered into dedicated recovery cylinders before the unit is disconnected, then sent for reclaim or disposal. Venting refrigerant to the air is illegal, so whoever removes an old unit should be F-Gas certified.

Air Source Heat Pump Systems

Monobloc and split systems, sized from a proper survey.

Find out more →

Heating System Repair

Fault-finding on heat pumps, boilers and controls.

Find out more →

Commercial Heating

Leak checks and maintenance for larger systems.

Find out more →

Need an F-Gas Engineer?

Call us with the make and model of your heat pump and what it's doing, and we'll take it from there.